SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Viessmann
83Viessmann · Vitotronic 200

83 on a Viessmann Vitotronic 200: Mains voltage too low

Short answer

On a Viessmann heat pump, 83 means: Mains voltage too low. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Mains voltage too low.
  • Mains voltage too low or intermediate circuit voltage too low.
  • Vitocal 300-G/333-G: Mains voltage too low or intermediate circuit voltage too low.
  • Mains voltage too low (< 380 V~) or intermediate circuit voltage too low.
  • Voltage at inverter too low.

Part involved: Mains voltage too low; Mains voltage too low or intermediate circuit voltage too low; Vitocal 300-G/333-G: Mains voltage too low or intermediate circuit voltage too low; Mains voltage too low (< 380 V~) or intermediate circuit voltage too …; Voltage at inverter too low.

When it shows: Type "Note" (H) - triggers "07 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF.

Likely causes:

  • Mains voltage too low.
  • Mains voltage too low or intermediate circuit voltage too low.
  • Vitocal 300-G/333-G: Mains voltage too low or intermediate circuit voltage too low.
  • Mains voltage too low (< 380 V~) or intermediate circuit voltage too low.
  • Voltage at inverter too low.

Is it safe?

Does the heat pump stop?Yes
SeverityWarning
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.

What the engineer will check

  • Test mains voltage at mains terminals: If mains voltage is too low (– 10 %), clarify the cause in consultation with the power supply utility.
  • Test mains voltage at mains terminals: If mains voltage is too low (10 %), – clarify the cause in consultation with the power supply utility.
  • No action required: Compressor is automatically reset.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026