SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Viessmann
80Viessmann · Vitotronic 200

80 on a Viessmann Vitotronic 200: Max. compressor current exceeded

Short answer

On a Viessmann heat pump, 80 means: Max. compressor current exceeded. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Max. compressor current exceeded.
  • Vitocal 300-G/333-G: Max. compressor current exceeded.

Part involved: Max. compressor current exceeded; Vitocal 300-G/333-G: Max. compressor current exceeded.

When it shows: Type "Note" (H) - triggers "07 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF.

Likely causes:

  • Max. compressor current exceeded.
  • Vitocal 300-G/333-G: Max. compressor current exceeded.

Is it safe?

Does the heat pump stop?Yes
SeverityWarning
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.

What the engineer will check

  • Test coil resistance at compressor. Resistance on all windings must be similar (± 10 %). For m Ω use a suitable measuring device.
  • Test coil resistance at compressor. Resistance on all windings must be similar (±10 %). For mΩ use a suitable measuring device.
  • No action required: Compressor is automatically reset.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026