Heat pumps · Error codes · Viessmann
71Viessmann · Vitotronic 200

71 on a Viessmann Vitotronic 200: Short circuit/lead break, secondary circuit return temperature sensor

Short answer

On a Viessmann heat pump, 71 means: Short circuit/lead break, secondary circuit return temperature sensor. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Short circuit/lead break, secondary circuit return temperature sensor.
  • Room temp. sensor HC2: No frost protection mode via room temperature sensor; No room temperature hook-up; No room temperature-dependent control.

Part involved: Short circuit/lead break, secondary circuit return temperature sensor; Room temp. sensor HC2.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF No frost protection mode via room temperature sensor; No room temperature hook-up; No room temperature-dependent control.

Likely causes:

  • Short circuit/lead break, secondary circuit return temperature sensor.
  • Short circuit, room temperature sensor, heating circuit with mixer M2/HC2.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the room thermostat/remote control and time-program settings are as expected.

What the engineer will check

  • Check resistance value (NTC 10 k) Ω at connection J21 (T3) of the EEV PCB: See "EEV PCB [4-6] / [4-7] ".
  • Check remote control. Replace remote control if required: See "Vitotrol" installation and service instructions.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.