6E on a Viessmann Vitotronic 200: Defrosting: Secondary circuit flow temperature too low
Short answer
On a Viessmann heat pump, 6E means: Defrosting: Secondary circuit flow temperature too low. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manuals for this range word it in different ways:
- Defrosting: Secondary circuit flow temperature too low.
- Flow sens condenser: No central cooling, no defrosting; Max. flow temperature in secondary circuit: Secondary circuit return temperature plus 5 K.
Part involved: Defrosting: Secondary circuit flow temperature too low; Flow sens condenser.
When it shows: Type "Note" (H) - triggers "07 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor does not start. No central cooling, no defrosting; Max. flow temperature in secondary circuit: Secondary circuit return temperature plus 5 K.
Likely causes:
- Defrosting: Secondary circuit flow temperature too low.
- Short circuit/lead break, secondary circuit flow temperature sensor upstream of the instantaneous heating water heater.
Is it safe?
| Does the heat pump stop? | Not stated |
|---|---|
| Severity | Warning |
| Engineer needed? | Yes |
The manual does not say whether the heat pump stops.
Resetting itself: Not stated in 6150133.
Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.
What you can check
- This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
- Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
- You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
- Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
- Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.
- Check the outdoor unit (air source models) is not blocked by leaves, debris or snow.
What the engineer will check
- As for "AA Cancel defrost" : See.
- "Message overview" for the heat pump control unit. Add more heat from secondary circuit, e.g. via additional heating water buffer cylinder in the return.
- Check resistance value (Pt500A) at connection X25.3/ X25.4: See "Controller and sensor PCB".
Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.
Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).
What you might notice
Sources
- Service instructions Vitotronic 200 type WO1C heat pump control unit (air/water split & monobloc, brine/water) (6150133, 2023-07) ↗ · 6150133 VSA00004 · pages 170, 94 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026