Heat pumps · Error codes · Viessmann
65Viessmann · Vitotronic 200

65 on a Viessmann Vitotronic 200: Charge level sensor of refrigerant collector faulty

Short answer

On a Viessmann heat pump, 65 means: Charge level sensor of refrigerant collector faulty. The heat pump keeps running. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Charge level sensor of refrigerant collector faulty.
  • Buffer outlet temp.: Operation with temperature value of flow temperature sensor in the secondary circuit of the lead heat pump.

Part involved: Charge level sensor of refrigerant collector faulty; Buffer outlet temp.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor remains in operation. Operation with temperature value of flow temperature sensor in the secondary circuit of the lead heat pump.

Likely causes:

  • Charge level sensor of refrigerant collector faulty.
  • Short circuit/lead break, buffer outlet temperature sensor.

Is it safe?

Does the heat pump stop?No
Engineer needed?Yes

The heat pump keeps running.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Check plug at connection J25/J26: See "EEV PCB [4] ". Replace sensor if necessary.
  • Check resistance value (NTC 10 k Ω) at plug F23: See "Controller and sensor PCB".

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026