63Viessmann · Vitotronic 200

63 on a Viessmann Vitotronic 200: Lower outside temperature limit not reached

Short answer

On a Viessmann heat pump, 63 means: Lower outside temperature limit not reached. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Lower outside temperature limit not reached.
  • Boiler sensor ext HS: Mixer external heat generator opens fully as soon as the external heat generator is switched on.; Frost protection monitoring of external heat generator is not active.

Part involved: Lower outside temperature limit not reached; Boiler sensor ext HS.

When it shows: Type "Note" (H) - triggers "07 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Both compressors OFF Mixer external heat generator opens fully as soon as the external heat generator is switched on.; Frost protection monitoring of external heat generator is not active.

Likely causes:

  • Lower outside temperature limit not reached.
  • Short circuit, external heat generator boiler water temperature sensor.

Is it safe?

Does the heat pump stop?Not stated
SeverityWarning
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.

What the engineer will check

  • No action required.
  • Check resistance value (NTC 10 k Ω) at plug F20: See "Controller and sensor PCB".

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026