61 on a Viessmann Vitotronic 200: Fan fault

Short answer

On a Viessmann heat pump, 61 means: Fan fault. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manuals for this range word it in different ways:

  • Fan fault.
  • Fan faulty.
  • Coolant buffer t sens.: No cooling operation with coolant buffer cylinder.

Part involved: Fan fault; Fan faulty; Coolant buffer t sens.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor runs on for max. 5 min. Type "Note" (H) - triggers "07 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor off: Message "A9 Heat pump" is displayed. No cooling operation with coolant buffer cylinder.

Likely causes:

  • Fan fault.
  • Fan faulty.
  • Short circuit, buffer temperature sensor, cooling.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).

What the engineer will check

  • Check if fan is blocked.
  • Carry out mechanical check of fan.
  • Check fan control or PWM signal at.
  • the controller PCB: See "Controller PCB and EEV PCB [6] ".
  • As for "A9 Heat pump" : See "Message overview" for the heat pump control unit.
  • Check resistance value (NTC 10 k Ω) at plug F26 (see "Controller and sensor PCB"); replace sensor if required.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026