Heat pumps · Error codes · Viessmann
60Viessmann · Vitotronic 200

60 on a Viessmann Vitotronic 200: DHW heating via auxiliary heat exchanger fault

Short answer

On a Viessmann heat pump, 60 means: DHW heating via auxiliary heat exchanger fault. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • DHW heating via auxiliary heat exchanger fault.
  • Buffer temp. sensor: For central heating: For central cooling with heating water/coolant buffer; Buffer cylinder is heated once every hour. cylinder:; Heating stops when the temperature at the secon-; Heating ….

Part involved: DHW heating via auxiliary heat exchanger fault; Buffer temp. sensor.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: DHW heating is stopped. For central heating: For central cooling with heating water/coolant buffer; Buffer cylinder is heated once every hour. cylinder:; Heating stops when the temperature at the secon-; Heating water/coolant buffer cylinder is cooled once dary circuit return temperature sensor reaches the ….

Likely causes:

  • DHW heating via auxiliary heat exchanger fault.
  • Short circuit, buffer temperature sensor.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.

What the engineer will check

  • Check auxiliary heat exchanger flow.
  • rate. Check circulation pump for cylinder.
  • heating. Check cylinder loading pump.
  • Check resistance value (NTC 10 k Ω) at plug F4: See "Controller and sensor PCB".

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026