Heat pumps · Error codes · Viessmann
5FViessmann · Vitotronic 200

5F on a Viessmann Vitotronic 200: Communication error for the following temperature sensors: Reversible suction gas; temperature sensor Secondary circuit flow; temperature sensor (upstream of instantaneous heating water heater) Liquid gas temperature; sensor

Short answer

On a Viessmann heat pump, 5F means: Communication error for the following temperature sensors: Reversible suction gas; temperature sensor Secondary circuit flow; temperature sensor (upstream of instantaneous heating water heater) Liquid gas temperature; sensor. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Communication error for the following temperature sensors: Reversible suction gas; temperature sensor Secondary circuit flow; temperature sensor (upstream of instantaneous heating water heater) Liquid gas temperature; sensor.

Part involved: Communication error for the following temperature sensors: Reversible suction gas; temperature sensor ….

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF.

Likely causes:

  • Communication error for the following temperature sensors: Reversible suction gas; temperature sensor Secondary circuit flow; temperature sensor (upstream of instantaneous heating water heater) Liquid gas ….

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.

What the engineer will check

  • As for "EF Modbus subscriber" : See "Message overview" for the heat pump control unit.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026