Heat pumps · Error codes · Viessmann
59Viessmann · Vitotronic 200

59 on a Viessmann Vitotronic 200: Electronic expansion valve faulty

Short answer

On a Viessmann heat pump, 59 means: Electronic expansion valve faulty. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Electronic expansion valve faulty.
  • Electronic expansion valve for suction gas superheating faulty.

Part involved: Electronic expansion valve faulty; Electronic expansion valve for suction gas superheating faulty.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF.

Likely causes:

  • Electronic expansion valve faulty.
  • Electronic expansion valve for suction gas superheating faulty.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.

What the engineer will check

  • Check plug at connection J7: See "EEV PCB [4-3] / [4-4] ".
  • Check stepper motor of electronic expansion valve.
  • Check plug at connection J7: See "EEV PCB [4-6] / [4-7] ".
  • Check plug at connection J11: See "EEV PCB [4] ".

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026