52Viessmann · Vitotronic 200

52 on a Viessmann Vitotronic 200: Cylinder sensor bottom: If only the lower cylinder temperature sensor is present: No DHW heating; If an additional upper temperature sensor is installed: DHW heating possible, switched on and off …

Short answer

On a Viessmann heat pump, 52 means: Cylinder sensor bottom: If only the lower cylinder temperature sensor is present: No DHW heating; If an additional upper temperature sensor is installed: DHW heating possible, switched on and off …. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Cylinder sensor bottom: If only the lower cylinder temperature sensor is present: No DHW heating; If an additional upper temperature sensor is installed: DHW heating possible, switched on and off ….

Part involved: Cylinder sensor bottom.

When it shows: If only the lower cylinder temperature sensor is present: No DHW heating; If an additional upper temperature sensor is installed: DHW heating possible, switched on and off via this sensor.

Likely causes:

  • Short circuit, bottom cylinder temperature sensor.

Is it safe?

Does the heat pump stop?Partly
SeverityWarning
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated per code; Vitotronic messages remain until the cause is removed and are acknowledged with OK (6150133 p.82). Unremedied acknowledged faults are redisplayed the following day.

Manual reset: Acknowledge with OK on the programming unit (user level permitted per 5817913 p.56-57) after the cause is remedied.

What you can check

  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).

What the engineer will check

  • Check resistance value (NTC 10 k Ω) at plug F7 or at terminals X25.7/X25.8: See "Controller and sensor PCB".

Who to ask for: Viessmann-trained heat pump installer/service engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.