Short answer

On a Viessmann heat pump, 4C means: Suction gas superheating too high. The heat pump stops until the fault clears or is reset.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Suction gas superheating too high.
  • Flow sensor cooling: If "Enable flow temperature sensor cooling circuit 7109" is set to "0", cooling operation is possible, otherwise no cooling.

Part involved: Suction gas superheating too high; Flow sensor cooling.

When it shows: No type given. Heat pump characteristics: Compressor OFF If "Enable flow temperature sensor cooling circuit 7109" is set to "0", cooling operation is possible, otherwise no cooling.

Likely causes:

  • Suction gas superheating too high.
  • Lead break, flow temperature sensor, cooling circuit.

Is it safe?

Does the heat pump stop?Yes
SeverityInformation only
Engineer needed?No

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.
  • Check the room thermostat/remote control and time-program settings are as expected.

What the engineer will check

  • Check whether the correct coding.
  • card is fitted. To check information, see "System information". In the event of recurrence: Have the.
  • refrigerant circuit checked by a refrigeration engineer.
  • Check whether the correct coding card is fitted. To check information, see "System information".
  • In the event of recurrence: Have the refrigerant circuit checked by a refrigeration engineer.
  • Check resistance value (NTC 10 k Ω) at plug F14: See "Controller and sensor PCB".

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.