4B on a Viessmann Vitotronic 200: EEV connecting cable faulty; EEV stepper motor faulty

Short answer

On a Viessmann heat pump, 4B means: EEV connecting cable faulty; EEV stepper motor faulty. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • EEV connecting cable faulty; EEV stepper motor faulty.
  • Flow sensor system: Flow temperature in heating circuit without mixer A1/HC1 is regulated via the return temperature sensor of the heat pump, no frost protection for this heating circuit.; Mixer ….

Part involved: EEV connecting cable faulty; EEV stepper motor faulty; Flow sensor system.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Both compressors OFF Flow temperature in heating circuit without mixer A1/HC1 is regulated via the return temperature sensor of the heat pump, no frost protection for this heating circuit.; Mixer external heat generator does not open.

Likely causes:

  • EEV connecting cable faulty; EEV stepper motor faulty.
  • Lead break, system flow temperature sensor (downstream of buffer cylinder).

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Check the EEV connecting cable. Replace the connecting cable if necessary.
  • Replace EEV.
  • Check resistance value (NTC 10 k Ω) at plug F13: See "Controller and sensor PCB".
  • If system flow temperature is not required: Check whether this sensor has been unintentionally activated ("Common flow temperature sensor system 701B").

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026