4B on a Viessmann Vitotronic 200: EEV connecting cable faulty; EEV stepper motor faulty
Short answer
On a Viessmann heat pump, 4B means: EEV connecting cable faulty; EEV stepper motor faulty. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manuals for this range word it in different ways:
- EEV connecting cable faulty; EEV stepper motor faulty.
- Flow sensor system: Flow temperature in heating circuit without mixer A1/HC1 is regulated via the return temperature sensor of the heat pump, no frost protection for this heating circuit.; Mixer ….
Part involved: EEV connecting cable faulty; EEV stepper motor faulty; Flow sensor system.
When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Both compressors OFF Flow temperature in heating circuit without mixer A1/HC1 is regulated via the return temperature sensor of the heat pump, no frost protection for this heating circuit.; Mixer external heat generator does not open.
Likely causes:
- EEV connecting cable faulty; EEV stepper motor faulty.
- Lead break, system flow temperature sensor (downstream of buffer cylinder).
Is it safe?
| Does the heat pump stop? | Not stated |
|---|---|
| Engineer needed? | Yes |
The manual does not say whether the heat pump stops.
Resetting itself: Not stated in 6150133.
Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.
What you can check
- This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
- Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
- You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
- Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.
What the engineer will check
- Check the EEV connecting cable. Replace the connecting cable if necessary.
- Replace EEV.
- Check resistance value (NTC 10 k Ω) at plug F13: See "Controller and sensor PCB".
- If system flow temperature is not required: Check whether this sensor has been unintentionally activated ("Common flow temperature sensor system 701B").
Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.
Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).
What you might notice
Sources
- Service instructions Vitotronic 200 type WO1C heat pump control unit (air/water split & monobloc, brine/water) (6150133, 2023-07) ↗ · 6150133 VSA00004 · pages 181, 92 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026