SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Viessmann
49Viessmann · Vitotronic 200

49 on a Viessmann Vitotronic 200: Evaporator max. operating pressure (MOP) has been reached; changeover from superheating to pressure control of the suction gas

Short answer

On a Viessmann heat pump, 49 means: Evaporator max. operating pressure (MOP) has been reached; changeover from superheating to pressure control of the suction gas. The heat pump keeps running.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Evaporator max. operating pressure (MOP) has been reached; changeover from superheating to pressure control of the suction gas.
  • Flow sensor HC3: Mixer heating circuit M3/HC3 is closed.

Part involved: Evaporator max. operating pressure (MOP) has been reached; changeover from superheating to …; Flow sensor HC3.

When it shows: No type given. Heat pump characteristics: Compressor remains in operation. Mixer heating circuit M3/HC3 is closed.

Likely causes:

  • Evaporator max. operating pressure (MOP) has been reached; changeover from superheating to pressure control of the suction gas.
  • Lead break, flow temperature sensor, heating circuit with mixer M3/HC3.

Is it safe?

Does the heat pump stop?No
SeverityInformation only
Engineer needed?No

The heat pump keeps running.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • No action required.
  • Check sensor: See mixer extension kit installation instructions.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026