Heat pumps · Error codes · Viessmann
39Viessmann · Vitotronic 200

39 on a Viessmann Vitotronic 200: Difference between flow temperature in the appliance and return temperature is larger than 12 K prior to defrosting

Short answer

On a Viessmann heat pump, 39 means: Difference between flow temperature in the appliance and return temperature is larger than 12 K prior to defrosting. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Difference between flow temperature in the appliance and return temperature is larger than 12 K prior to defrosting.
  • Hot gas temperature limit exceeded.
  • Return sensor primary: Operation with temperature value of flow temperature sensor in primary circuit, minus 2 K.; If the primary circuit flow and return temperature sensors are both faulty at ….

Part involved: Difference between flow temperature in the appliance and return temperature is larger …; Hot gas temperature limit exceeded; Return sensor primary.

When it shows: Type "Note" (H) - triggers "07 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Defrosting procedure does not start. Type "Note" (H) - triggers "07 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF Operation with temperature value of flow temperature sensor in primary circuit, minus 2 K.; If the primary circuit flow and return temperature sensors are both faulty at the same time, the message "A9 Heat pump" is displayed and the heat ….

Likely causes:

  • Difference between flow temperature in the appliance and return temperature is larger than 12 K prior to defrosting.
  • Hot gas temperature limit exceeded.
  • Lead break, return temperature sensor, primary circuit (heat pump air discharge or brine outlet).

Is it safe?

Does the heat pump stop?Not stated
SeverityWarning
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Reduce heat demand in the secondary circuit, e.g. lower the set room temperatures. Reduce heat transfer in the secondary circuit.
  • Check whether the coding card matches the heat pump. To check information, see "System information".
  • Check resistance value (Pt500A) at terminals X25.3/ X25.4: See "Controller and sensor PCB".

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026