34 on a Viessmann Vitotronic 200: Evaporation temperature too low

Short answer

On a Viessmann heat pump, 34 means: Evaporation temperature too low. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manuals for this range word it in different ways:

  • Evaporation temperature too low.
  • Hot gas temp. 2: Compressor may shut down as a result of changed refrigerant circuit conditions (only heat pumps without electronic expansion valve).

Part involved: Evaporation temperature too low; Hot gas temp. 2.

When it shows: Type "Note" (H) - triggers "07 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Cooling mode:; Compressor OFF Heating mode:; Compressor remains in operation. Compressor may shut down as a result of changed refrigerant circuit conditions (only heat pumps without electronic expansion valve).

Likely causes:

  • Evaporation temperature too low.
  • Hot gas temperature sensor short circuit, heat pump stage 2.

Is it safe?

Does the heat pump stop?Yes
SeverityWarning
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Check reversible suction gas temperature sensor: Check resistance value (Pt500A) at connection X25.15/X25.16 of the controller and sensor PCB: See "Controller and sensor PCB".
  • Check resistance value (Pt500A) at terminals X25.17/ X25.18 (see "Controller and sensor PCB"); replace sensor if required.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026