Heat pumps · Error codes · Viessmann
31Viessmann · Vitotronic 200

31 on a Viessmann Vitotronic 200: Max. differential between evaporation and condensation temperature reached

Short answer

On a Viessmann heat pump, 31 means: Max. differential between evaporation and condensation temperature reached. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Max. differential between evaporation and condensation temperature reached.
  • Return sensor primary: Operation with temperature value of flow temperature sensor in primary circuit, minus 2 K.; If the primary circuit flow and return temperature sensors are both faulty at ….

Part involved: Max. differential between evaporation and condensation temperature reached; Return sensor primary.

When it shows: Type "Note" (H) - triggers "07 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF Operation with temperature value of flow temperature sensor in primary circuit, minus 2 K.; If the primary circuit flow and return temperature sensors are both faulty at the same time, the message "A9 Heat pump" is displayed and the heat ….

Likely causes:

  • Max. differential between evaporation and condensation temperature reached.
  • Short circuit, primary circuit return temperature sensor (heat pump air discharge or brine outlet).

Is it safe?

Does the heat pump stop?Yes
SeverityWarning
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Lower secondary circuit flow temperature: Adapt parameters for room heating,.
  • e.g. set room temperature, heating curve, etc. Reduce the set cylinder temperature.
  • Check resistance value (Pt500A) at terminals X25.3/ X25.4: See "Controller and sensor PCB".

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026