25Viessmann · Vitotronic 200

25 on a Viessmann Vitotronic 200: Operating point is outside the application limits

Short answer

On a Viessmann heat pump, 25 means: Operating point is outside the application limits. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Operating point is outside the application limits.
  • LPG temp. sensor: Compressor stops.

Part involved: Operating point is outside the application limits.; LPG temp. sensor.

When it shows: Type "Note" (H) - triggers "07 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Both compressors OFF Compressor stops.

Likely causes:

  • Operating point is outside the application limits.
  • Short circuit, LPG temperature sensor.

Is it safe?

Does the heat pump stop?Not stated
SeverityWarning
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).

What the engineer will check

  • Check the position of the operating point: See "Compressor travel" and/or "Compressor path".
  • Check resistance value (Pt500A) at terminals X25.17/ X25.18: See "Controller and sensor PCB".

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026