Heat pumps · Error codes · Viessmann
18Viessmann · Vitotronic 200

18 on a Viessmann Vitotronic 200: Compressor fault (general message)

Short answer

On a Viessmann heat pump, 18 means: Compressor fault (general message). The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Compressor fault (general message).
  • Vitocal 300-G/333-G: Compressor fault (general message).
  • Outside temp. sensor: An outside temperature value of – 40 °C is used to calculate the set flow temperature.

Part involved: Compressor fault (general message); Vitocal 300-G/333-G: Compressor fault (general message); Outside temp. sensor.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Subject to other messages An outside temperature value of – 40 °C is used to calculate the set flow temperature.

Likely causes:

  • Compressor fault (general message).
  • Vitocal 300-G/333-G: Compressor fault (general message).
  • Lead break, outside temperature sensor.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.
  • Check the outdoor unit (air source models) is not blocked by leaves, debris or snow.

What the engineer will check

  • See further messages regarding the compressor and inverter (message code "80" and above).
  • Check resistance value (NTC 10 k Ω) at plug F0: See "Controller and sensor PCB".

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026