09 on a Viessmann Vitotronic 200: Short circuit/lead break evaporator temperature sensor

Short answer

On a Viessmann heat pump, 09 means: Short circuit/lead break evaporator temperature sensor. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Short circuit/lead break evaporator temperature sensor.
  • Short circuit/lead break, defrost temperature sensor.
  • Electricity meter PV: Utilisation of PV power generated on site not possible.

Part involved: Short circuit/lead break evaporator temperature sensor; Short circuit/lead break, defrost temperature sensor; Electricity meter PV.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor may stop due to a change in refrigerant circuit conditions. Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Cooling mode:; Compressor remains in operation. Heating mode:; Compressor OFF Utilisation of PV power generated on site not possible.

Likely causes:

  • Short circuit/lead break evaporator temperature sensor.
  • Short circuit/lead break, defrost temperature sensor.
  • code Phase 1 Phase 2 Phase 3 "01" X "02" X "03" X X "04" X "05" X X "06" X X "07" X X ….

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).

What the engineer will check

  • Check resistance value (Pt500A) at the sensor connection of the EEV PCB: See "EEV PCB [2] ".
  • Check resistance value (NTC 20 k) Ω at connection T-SENSOR2 on the main PCB: See "Main PCB [7] / [7-1] ".
  • Have electricity meter checked by an electrical engineer.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump engineer / qualified electrician.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only); Qualified electrician for work on electrical equipment (Viessmann safety instructions).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.