08 on a Viessmann Vitotronic 200: Short circuit/lead break, secondary circuit return temperature sensor

Short answer

On a Viessmann heat pump, 08 means: Short circuit/lead break, secondary circuit return temperature sensor. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manuals for this range word it in different ways:

  • Short circuit/lead break, secondary circuit return temperature sensor.
  • Refrigerant circuit 2.

Part involved: Short circuit/lead break, secondary circuit return temperature sensor; Refrigerant circuit 2.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Operation with temperature value of flow temperature sensor in secondary circuit, minus 5 K.

Likely causes:

  • Short circuit/lead break, secondary circuit return temperature sensor.
  • Last message in message histo- Message from refrigerant circuit conry, refrigerant circuit troller, heat pump stage 2 (if installed).

Is it safe?

Does the heat pump stop?Partly
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Check resistance value (Pt500A) at the sensor connection of the EEV PCB: See "EEV PCB [2] ".
  • Check resistance value (NTC 10 k Ω) at sensor connection on the controller PCB: See "Controller PCB and EEV PCB [6] ".
  • Observe "Diagnosis" "Refrigerant circuit" "Message history".

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026