SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Viessmann
07Viessmann · Vitotronic 200

07 on a Viessmann Vitotronic 200: Short circuit/lead break liquid gas temperature sensor 2 (downstream of the EEV)

Short answer

On a Viessmann heat pump, 07 means: Short circuit/lead break liquid gas temperature sensor 2 (downstream of the EEV). The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Short circuit/lead break liquid gas temperature sensor 2 (downstream of the EEV).
  • Refrigerant circuit.

Part involved: Short circuit/lead break liquid gas temperature sensor 2 (downstream of the EEV); Refrigerant circuit.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor remains in; operation. Energy statement is not; calculated correctly: See chapter "Diagnosis, energy statement".

Likely causes:

  • Short circuit/lead break liquid gas temperature sensor 2 (downstream of the EEV).
  • Last message in message histo- Message from refrigerant circuit conry, refrigerant circuit troller, heat pump stage 1.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Check resistance value (Pt500A) at the sensor connection of the EEV PCB: See "EEV PCB [2] ".
  • Observe "Diagnosis" "Refrigerant circuit" "Message history".

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026