05 on a Viessmann Vitotronic 200: Short circuit/lead break, high pressure sensor

Short answer

On a Viessmann heat pump, 05 means: Short circuit/lead break, high pressure sensor. The heat pump keeps running. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Short circuit/lead break, high pressure sensor.
  • Short circuit/lead break, high pressure sensor (liquid gas pressure sensor).
  • Refrigerant circuit.

Part involved: Short circuit/lead break, high pressure sensor; Short circuit/lead break, high pressure sensor (liquid gas pressure sensor); Refrigerant circuit.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics:; Compressor remains in operation.; Energy statement is not calculated correctly: See chapter "Diagnosis, energy statement". Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Both compressors OFF Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics:; Compressor OFF; Energy statement is not calculated correctly: See chapter "Diagnosis, Energy statement".

Likely causes:

  • Short circuit/lead break, high pressure sensor.
  • Short circuit/lead break, high pressure sensor (liquid gas pressure sensor).
  • Last message in message histo- Fault message from the refrigerant ry, refrigerant circuit circuit controller.

Is it safe?

Does the heat pump stop?No
Engineer needed?Yes

The heat pump keeps running.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.

What the engineer will check

  • Test voltage at the high pressure sensor connection: See "EEV PCB [2] ". 0.5 V: 0 bar.
  • 4.5 V: Max. pressure, see sensor imprint.
  • Check current at connection J10 (P2) of the EEV PCB: See "EEV PCB [4-3] / [4-4] ". Take refrigerant R410A into account.
  • Check current at connection J10 (P2) of the EEV PCB: See "EEV PCB [4-6] / [4-7] ". Take refrigerant R410A into account.
  • Check current at connection J10 (P2) on the EEV PCB: See "EEV PCB [4] ". Take refrigerant R410A into account.
  • Test voltage at the high pressure sensor connection: See "Controller PCB and EEV PCB [6] ". 0.5 V: 0 bar.
  • Check current at connection H_PRESS on the main PCB: See "Main PCB [7] / [7-1] ". Take refrigerant into account.
  • Check cable and main PCB.
  • Observe "Diagnosis" "Refrigerant circuit" "Message history".

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026