SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Viessmann
04Viessmann · Vitotronic 200

04 on a Viessmann Vitotronic 200: Short circuit/lead break, hot gas temperature sensor

Short answer

On a Viessmann heat pump, 04 means: Short circuit/lead break, hot gas temperature sensor. The heat pump keeps running. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Short circuit/lead break, hot gas temperature sensor.
  • Short circuit/lead break, hot gas temperature sensor, compressor (discharged).
  • Elec. heating blocked: The instantaneous heating water heater is not started, not even for frost protection. ! Please note If the compressor does not start, the system may no longer ….

Part involved: Short circuit/lead break, hot gas temperature sensor; Short circuit/lead break, hot gas temperature sensor, compressor (discharged); Elec. heating blocked.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics:; Compressor remains in operation.; Energy statement is not calculated correctly: See chapter "Diagnosis, energy statement". Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Both compressors OFF Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Cooling mode:; Compressor remains in operation. Heating mode:; Compressor OFF The instantaneous heating water heater is not started, not even for frost protection. ! Please note If the compressor does not start, the system may no longer be protected against frost. Ensure frost protection on site.

Likely causes:

  • Short circuit/lead break, hot gas temperature sensor.
  • Short circuit/lead break, hot gas temperature sensor, compressor (discharged).
  • The prompt "Secondary circuit filled?" during enabling of the instantaneous heating water heater was answered with "No". "Enable instantaneous heating water heater 7900" is automatically ….

Is it safe?

Does the heat pump stop?No
Engineer needed?Yes

The heat pump keeps running.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.

What the engineer will check

  • Check resistance value (Pt500A) at the sensor connection of the EEV PCB: See "EEV PCB [2] ".
  • Check resistance value (NTC 10 k) Ω at connection J13 (T6) of the EEV PCB: See "EEV PCB [4-3] / [4-4] ".
  • Check resistance value (NTC 10 k) Ω at connection J13 (T6) of the EEV PCB: See "EEV PCB [4-6] / [4-7] ".
  • Check resistance value (NTC 10 k) Ω at sensor connection on the EEV PCB: See "Controller PCB and EEV PCB [6] ".
  • Check resistance value (NTC 50 k) Ω at connection T-SENSOR2 on the main PCB: See "Main PCB [7] / [7-1] ".
  • Fill and vent the secondary circuit. Then enable the instantaneous heating water heater: Set "Enable instantaneous heating water heater 7900" to "1". Confirm prompt "Secondary ….

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026