03 on a Viessmann Vitotronic 200: Short circuit/lead break suction gas temperature sensor

Short answer

On a Viessmann heat pump, 03 means: Short circuit/lead break suction gas temperature sensor. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Short circuit/lead break suction gas temperature sensor.
  • Short circuit/lead break, suction gas temperature sensor.
  • Configuration fault: Limited or no heat pump and/or heating system functionality Reading an additional code The additional 2-digit code contains further information (additional messages). Each digit is a hexadecimal value. ….

Part involved: Short circuit/lead break suction gas temperature sensor; Short circuit/lead break, suction gas temperature sensor; Configuration fault.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF; Energy statement is not; calculated correctly: See chapter "Diagnosis, Energy statement". Limited or no heat pump and/or heating system functionality Reading an additional code The additional 2-digit code contains further information (additional messages). Each digit is a hexadecimal value. The numbers of the additional messages can be read from the hexadecimal ….

Likely causes:

  • Short circuit/lead break suction gas temperature sensor.
  • Short circuit/lead break, suction gas temperature sensor.
  • 1st digit of the additional code 1st digit 1 Incorrect system scheme for central heating via ventilation unit 2 "Min. suction pressure 5086" set higher ….
  • Incorrect solar control unit set ("Type solar control unit 7A00").
  • AM1 extension not enabled ("External extension 7010").
  • Coolant buffer cylinder is enabled at the same time Values from example 2nd digit of the additional code 2nd digit 1 Incorrect system scheme (contains ….
  • Room temperature sensor for cooling set from unavailable remote control.
  • "Max. flow temperature heating circuit 200E" set lower than "Min. flow temperature cooling 7103".

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.
  • Check the outdoor unit (air source models) is not blocked by leaves, debris or snow.

What the engineer will check

  • Check resistance value (Pt500A) at the sensor connection of the EEV PCB: See "EEV PCB [2] ".
  • Check resistance value (NTC 10 k Ω) at connection J13 (T4) of the EEV PCB: See "EEV PCB [4-3] / [4-4] ".
  • Check resistance value (NTC 10 k Ω) at connection J13 (T4) of the EEV PCB: See "EEV PCB [4-6] / [4-7] ".
  • Check resistance value (NTC 10 k) Ω at connection J21 (T7) on the EEV PCB: See "EEV PCB [4] ".
  • Check resistance value (NTC 20 k Ω) at connection T-SENSOR3 on the main PCB: See "Main PCB [7] / [7-1] ".
  • Check and adjust relevant parameters. If necessary, restore factory settings (reset) and reconfigure system. Contact a heat pump specialist certified by Viessmann if the cause ….

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.