Heat pumps · Error codes · Toshiba
L15Toshiba

L15 on a Toshiba heat pump: Combination failure

Short answer

On a Toshiba heat pump, L15 means: Combination failure. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 4 sources

What it means

On the R32 Estia 1-Series (split, Wall-Mounted and All-in-One)

The manual says: Combination failure.

Part involved: DIP switches, DN/FC codes, addresses, model combination.

When it shows: Hydro unit model name differs (detected by outdoor unit).

Likely causes:

  • Hydro unit model.
  • DN 6BD setting.

On the Estia (Series 4) Standard & Powerful

The manual says: Combination error - model code of hydro unit is different (Powerful type only).

Part involved: DIP switches, DN/FC codes, addresses, model combination.

When it shows: Model name of the outdoor unit is different.

Likely causes:

  • Outdoor unit model.

On the Estia 5 Series (Standard)

The manual says: Combination error.

Part involved: DIP switches, DN/FC codes, addresses, model combination.

When it shows: Model name of the outdoor unit is different.

Likely causes:

  • Outdoor unit model.

On the Estia 5 Series Powerful (Hi Power / Extreme)

The manual says: Combination error - model name of the hydro unit is different (outdoor detected).

Part involved: DIP switches, DN/FC codes, addresses, model combination.

Likely causes:

  • Hydro unit model.
  • DP_SW13_4 ON.

Is it safe?

On the R32 Estia 1-Series (split, Wall-Mounted and All-in-One)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Cause must be fixed by an engineer; hardware faults reappear until repaired.

On the Estia (Series 4) Standard & Powerful

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no.

Manual reset: Cause must be fixed by an engineer; hardware faults reappear until repaired.

On the Estia 5 Series (Standard)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Cause must be fixed by an engineer; hardware faults reappear until repaired.

On the Estia 5 Series Powerful (Hi Power / Extreme)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Cause must be fixed by an engineer; hardware faults reappear until repaired.

What you can check

  • Note the check code shown on the remote controller and the outdoor/hydro model numbers before contacting an engineer.

What the engineer will check

On the R32 Estia 1-Series (split, Wall-Mounted and All-in-One)

  • Follow manufacturer's check-code flowchart.
  • Hydro unit model.
  • DN 6BD setting.

Who to ask for: Installer / commissioning engineer (Toshiba Estia).

Certification: Manufacturer training advantageous.

On the Estia (Series 4) Standard & Powerful

  • Follow manufacturer's check-code flowchart.
  • Outdoor unit model.

Who to ask for: Installer / commissioning engineer (Toshiba Estia).

Certification: Manufacturer training advantageous.

On the Estia 5 Series (Standard)

  • Follow manufacturer's check-code flowchart.
  • Outdoor unit model.

Who to ask for: Installer / commissioning engineer (Toshiba Estia).

Certification: Manufacturer training advantageous.

On the Estia 5 Series Powerful (Hi Power / Extreme)

  • Follow manufacturer's check-code flowchart.
  • Hydro unit model.
  • DP_SW13_4 ON.

Who to ask for: Installer / commissioning engineer (Toshiba Estia).

Certification: Manufacturer training advantageous.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026