A05 on a Toshiba heat pump: Piping antifreeze operation

Short answer

On a Toshiba heat pump, A05 means: Piping antifreeze operation. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 4 sources

What it means

On the R32 Estia 1-Series (split, Wall-Mounted and All-in-One)

The manual says: Piping antifreeze operation.

Part involved: backup heater, overheat thermostat, cylinder immersion and thermal cut-out.

When it shows: Heater on with TWO/TWI/THO<4C does not reach >=5C within 30 min.

Likely causes:

  • Heater power circuit (supply, breaker, connection).
  • TWI/TWO/THO sensors.
  • Backup heater disconnected.

On the Estia (Series 4) Standard & Powerful

The manual says: Piping antifreeze operation.

Part involved: backup heater, overheat thermostat, cylinder immersion and thermal cut-out.

When it shows: Heater on with TWO/TWI/THO<4C does not reach >=5C in 30 min.

Likely causes:

  • Heater power circuit.
  • TWI/TWO/THO sensors.
  • Backup heater disconnected.

On the Estia 5 Series (Standard)

The manual says: Piping antifreeze operation.

Part involved: backup heater, overheat thermostat, cylinder immersion and thermal cut-out.

When it shows: Heater on with TWO/TWI/THO<4C does not reach >=5C in 30 min.

Likely causes:

  • Heater power circuit.
  • TWI/TWO/THO sensors.
  • Backup heater disconnected.

On the Estia 5 Series Powerful (Hi Power / Extreme)

The manual says: Piping antifreeze operation.

Part involved: backup heater, overheat thermostat, cylinder immersion and thermal cut-out.

When it shows: Trigger thresholds not printed in the IM; see SM.

Likely causes:

  • Heater power circuit.
  • TWI/TWO/THO sensors.
  • Backup heater disconnected.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: yes (per manual).

Manual reset: Clear the code from the remote controller once the cause is fixed (service procedure).

What you can check

  • Note the check code shown on the remote controller and the outdoor/hydro model numbers before contacting an engineer.
  • Check the consumer-unit breakers/isolators for the outdoor unit, hydro unit and backup heater are switched on.

What the engineer will check

On the R32 Estia 1-Series (split, Wall-Mounted and All-in-One)

  • Follow manufacturer's check-code flowchart.
  • Heater power circuit (supply, breaker, connection).
  • TWI/TWO/THO sensors.
  • Backup heater disconnected.

Who to ask for: Heat pump engineer with electrical competence.

Certification: Electrical competence (Part P / 18th Edition).

On the Estia (Series 4) Standard & Powerful

  • Follow manufacturer's check-code flowchart.
  • Heater power circuit.
  • TWI/TWO/THO sensors.
  • Backup heater disconnected.

Who to ask for: Heat pump engineer with electrical competence.

Certification: Electrical competence (Part P / 18th Edition).

On the Estia 5 Series (Standard)

  • Follow manufacturer's check-code flowchart.
  • Heater power circuit.
  • TWI/TWO/THO sensors.
  • Backup heater disconnected.

Who to ask for: Heat pump engineer with electrical competence.

Certification: Electrical competence (Part P / 18th Edition).

On the Estia 5 Series Powerful (Hi Power / Extreme)

  • Follow manufacturer's check-code flowchart.
  • Heater power circuit.
  • TWI/TWO/THO sensors.
  • Backup heater disconnected.

Who to ask for: Heat pump engineer with electrical competence.

Certification: Electrical competence (Part P / 18th Edition).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.