Heat pumps · Error codes · Toshiba
L10Toshiba

L10 on a Toshiba heat pump: Unset service PC board jumper

Short answer

On a Toshiba heat pump, L10 means: Unset service PC board jumper. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 4 sources

What it means

On the R32 Estia 1-Series (split, Wall-Mounted and All-in-One)

The manual says: Unset service PC board jumper.

Part involved: DIP switches, DN/FC codes, addresses, model combination.

When it shows: Jumpers not cut on replacement board.

Likely causes:

  • Cut J800-J803 (3-phase MCC-1781: J800-J802).

On the Estia (Series 4) Standard & Powerful

The manual says: Unset service PC board jumper.

Part involved: DIP switches, DN/FC codes, addresses, model combination.

When it shows: J800-J803 not cut.

Likely causes:

  • Cut J800-J803.

On the Estia 5 Series (Standard)

The manual says: Unset service PC board jumper.

Part involved: DIP switches, DN/FC codes, addresses, model combination.

When it shows: J800-J803 not cut.

Likely causes:

  • Cut J800-J803.

On the Estia 5 Series Powerful (Hi Power / Extreme)

The manual says: Unset service PC board jumper.

Part involved: DIP switches, DN/FC codes, addresses, model combination.

When it shows: Trigger thresholds not printed in the IM; see SM.

Likely causes:

  • Cut J800-J803.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no.

Manual reset: Cause must be fixed by an engineer; hardware faults reappear until repaired.

What you can check

  • Note the check code shown on the remote controller and the outdoor/hydro model numbers before contacting an engineer.

What the engineer will check

On the R32 Estia 1-Series (split, Wall-Mounted and All-in-One)

  • Follow manufacturer's check-code flowchart.
  • Cut J800-J803 (3-phase MCC-1781: J800-J802).

Who to ask for: Installer / commissioning engineer (Toshiba Estia).

Certification: Manufacturer training advantageous.

On the Estia (Series 4) Standard & Powerful

  • Follow manufacturer's check-code flowchart.
  • Cut J800-J803.

Who to ask for: Installer / commissioning engineer (Toshiba Estia).

Certification: Manufacturer training advantageous.

On the Estia 5 Series (Standard)

  • Follow manufacturer's check-code flowchart.
  • Cut J800-J803.

Who to ask for: Installer / commissioning engineer (Toshiba Estia).

Certification: Manufacturer training advantageous.

On the Estia 5 Series Powerful (Hi Power / Extreme)

  • Follow manufacturer's check-code flowchart.
  • Cut J800-J803.

Who to ask for: Installer / commissioning engineer (Toshiba Estia).

Certification: Manufacturer training advantageous.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026