E04 on a Toshiba heat pump: Regular communication failure between hydro unit and outdoor unit

Short answer

On a Toshiba heat pump, E04 means: Regular communication failure between hydro unit and outdoor unit. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 4 sources

What it means

On the R32 Estia 1-Series (split, Wall-Mounted and All-in-One)

The manual says: Regular communication failure between hydro unit and outdoor unit.

Part involved: interconnecting cable, remote controller, PCBs.

When it shows: Serial signal not received from outdoor unit.

Likely causes:

  • Miswiring of interconnecting cable between hydro and outdoor unit.
  • Serial circuit fault.

On the Estia (Series 4) Standard & Powerful

The manual says: Regular communication error between hydro unit and outdoor unit.

Part involved: interconnecting cable, remote controller, PCBs.

When it shows: Serial signal not received from outdoor unit.

Likely causes:

  • Miswiring of interconnecting cable.

On the Estia 5 Series (Standard)

The manual says: Regular communication error between hydro unit and outdoor unit.

Part involved: interconnecting cable, remote controller, PCBs.

When it shows: Serial signal not received from outdoor unit.

Likely causes:

  • Miswiring of interconnecting cable.

On the Estia 5 Series Powerful (Hi Power / Extreme)

The manual says: Regular communication error between hydro unit and outdoor unit.

Part involved: interconnecting cable, remote controller, PCBs.

When it shows: Trigger thresholds not printed in the IM; see SM.

Likely causes:

  • Miswiring of interconnecting cable.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: yes (per manual).

Manual reset: Clear the code from the remote controller once the cause is fixed (service procedure).

What you can check

  • Note the check code shown on the remote controller and the outdoor/hydro model numbers before contacting an engineer.
  • Check the consumer-unit breakers/isolators for the outdoor unit, hydro unit and backup heater are switched on.

What the engineer will check

On the R32 Estia 1-Series (split, Wall-Mounted and All-in-One)

  • Follow manufacturer's check-code flowchart.
  • Miswiring of interconnecting cable between hydro and outdoor unit.
  • Serial circuit fault.

Who to ask for: Heat pump engineer.

Certification: Electrical competence.

On the Estia (Series 4) Standard & Powerful

  • Follow manufacturer's check-code flowchart.
  • Miswiring of interconnecting cable.

Who to ask for: Heat pump engineer.

Certification: Electrical competence.

On the Estia 5 Series (Standard)

  • Follow manufacturer's check-code flowchart.
  • Miswiring of interconnecting cable.

Who to ask for: Heat pump engineer.

Certification: Electrical competence.

On the Estia 5 Series Powerful (Hi Power / Extreme)

  • Follow manufacturer's check-code flowchart.
  • Miswiring of interconnecting cable.

Who to ask for: Heat pump engineer.