A12Toshiba

A12 on a Toshiba heat pump: Heating, hot water heater failure

Short answer

On a Toshiba heat pump, A12 means: Heating, hot water heater failure. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 4 sources

What it means

On the R32 Estia 1-Series (split, Wall-Mounted and All-in-One)

The manual says: Heating, hot water heater failure.

Part involved: backup heater, overheat thermostat, cylinder immersion and thermal cut-out.

When it shows: Antifreeze control under TWI<15C and heater backup does not achieve TWI>=15C / TTW>=20C.

Likely causes:

  • Very large heating/DHW load.
  • Backup or cylinder heater power circuit (supply, breaker, connection).

On the Estia (Series 4) Standard & Powerful

The manual says: Heating, hot water heater error.

Part involved: backup heater, overheat thermostat, cylinder immersion and thermal cut-out.

When it shows: Antifreeze control with TWI<20C; heater backup does not achieve target.

Likely causes:

  • Very large heating/DHW load.
  • Backup or cylinder heater power circuit.

On the Estia 5 Series (Standard)

The manual says: Heating, hot water heater error.

Part involved: backup heater, overheat thermostat, cylinder immersion and thermal cut-out.

When it shows: Antifreeze control with TWI<15C; heater backup does not achieve TWI>=15C / TTW>=20C.

Likely causes:

  • Very large heating/DHW load.
  • Backup or cylinder heater power circuit.

On the Estia 5 Series Powerful (Hi Power / Extreme)

The manual says: Heating, hot water heater error.

Part involved: backup heater, overheat thermostat, cylinder immersion and thermal cut-out.

When it shows: Trigger thresholds not printed in the IM; see SM.

Likely causes:

  • Very large heating/DHW load.
  • Backup or cylinder heater power circuit.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: yes (per manual).

Manual reset: Clear the code from the remote controller once the cause is fixed (service procedure).

What you can check

  • Note the check code shown on the remote controller and the outdoor/hydro model numbers before contacting an engineer.
  • Check the consumer-unit breakers/isolators for the outdoor unit, hydro unit and backup heater are switched on.

What the engineer will check

On the R32 Estia 1-Series (split, Wall-Mounted and All-in-One)

  • Follow manufacturer's check-code flowchart.
  • Very large heating/DHW load.
  • Backup or cylinder heater power circuit (supply, breaker, connection).

Who to ask for: Heat pump engineer with electrical competence.

Certification: Electrical competence (Part P / 18th Edition).

On the Estia (Series 4) Standard & Powerful

  • Follow manufacturer's check-code flowchart.
  • Very large heating/DHW load.
  • Backup or cylinder heater power circuit.

Who to ask for: Heat pump engineer with electrical competence.

Certification: Electrical competence (Part P / 18th Edition).

On the Estia 5 Series (Standard)

  • Follow manufacturer's check-code flowchart.
  • Very large heating/DHW load.
  • Backup or cylinder heater power circuit.

Who to ask for: Heat pump engineer with electrical competence.

Certification: Electrical competence (Part P / 18th Edition).

On the Estia 5 Series Powerful (Hi Power / Extreme)

  • Follow manufacturer's check-code flowchart.
  • Very large heating/DHW load.
  • Backup or cylinder heater power circuit.

Who to ask for: Heat pump engineer with electrical competence.

Certification: Electrical competence (Part P / 18th Edition).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.