Heat pumps · Error codes · Toshiba
A07Toshiba

A07 on a Toshiba heat pump: Standard: pressure switch operation; Powerful: incorrect outdoor/hydro matching

Short answer

On a Toshiba heat pump, A07 means: Standard: pressure switch operation; Powerful: incorrect outdoor/hydro matching. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Estia (Series 4) Standard & Powerful

The manual says: Standard: pressure switch operation; Powerful: incorrect outdoor/hydro matching.

Part involved: refrigerant charge, PMV, valves, pressure switch/sensor.

When it shows: Standard: pressure switch operates 300 s continuously; Powerful: system set-up mismatch.

Likely causes:

  • Little or no water flow.
  • Flow switch defect.
  • Operation under heavy load.
  • Pressure switch defect.
  • DPSW13_4 setting (OFF = Standard, ON = Powerful).

On the Estia 5 Series (Standard)

The manual says: Pressure switch operation.

Part involved: refrigerant charge, PMV, valves, pressure switch/sensor.

When it shows: Pressure switch operates for 300 s continuously during heat pump operation.

Likely causes:

  • Little or no water flow.
  • Flow switch defect.
  • Operation under heavy load.
  • Pressure switch defect.

On the Estia 5 Series Powerful (Hi Power / Extreme)

The manual says: Combination error - model name of the hydro unit is different.

Part involved: DIP switches, DN/FC codes, addresses, model combination.

Likely causes:

  • DP_SW13_4 must be set ON for the Powerful series.

Is it safe?

On the Estia (Series 4) Standard & Powerful

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no.

Manual reset: Cause must be fixed by an engineer; hardware faults reappear until repaired.

On the Estia 5 Series (Standard)

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no.

Manual reset: Cause must be fixed by an engineer; hardware faults reappear until repaired.

On the Estia 5 Series Powerful (Hi Power / Extreme)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Cause must be fixed by an engineer; hardware faults reappear until repaired.

What you can check

On the Estia (Series 4) Standard & Powerful

  • Note the check code shown on the remote controller and the outdoor/hydro model numbers before contacting an engineer.
  • Check the outdoor unit is not blocked by leaves, debris, snow or ice, and that nothing is covering the air inlet/outlet.

On the Estia 5 Series (Standard)

  • Note the check code shown on the remote controller and the outdoor/hydro model numbers before contacting an engineer.
  • Check the outdoor unit is not blocked by leaves, debris, snow or ice, and that nothing is covering the air inlet/outlet.

On the Estia 5 Series Powerful (Hi Power / Extreme)

  • Note the check code shown on the remote controller and the outdoor/hydro model numbers before contacting an engineer.

What the engineer will check

On the Estia (Series 4) Standard & Powerful

  • Follow manufacturer's check-code flowchart.
  • Little or no water flow.
  • Flow switch defect.
  • Operation under heavy load.
  • Pressure switch defect.
  • DPSW13_4 setting (OFF = Standard, ON = Powerful).

Who to ask for: F-gas certified refrigeration / heat pump engineer.

Certification: F-gas Category I; R32 is A2L mildly flammable - trained handler required.

On the Estia 5 Series (Standard)

  • Follow manufacturer's check-code flowchart.
  • Little or no water flow.
  • Flow switch defect.
  • Operation under heavy load.
  • Pressure switch defect.

Who to ask for: F-gas certified refrigeration / heat pump engineer.

Certification: F-gas Category I; R32 is A2L mildly flammable - trained handler required.

On the Estia 5 Series Powerful (Hi Power / Extreme)

  • Follow manufacturer's check-code flowchart.
  • DP_SW13_4 must be set ON for the Powerful series.

Who to ask for: Installer / commissioning engineer (Toshiba Estia).

Certification: Manufacturer training advantageous.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026