Heat pumps · Error codes · Stiebel Eltron
35Stiebel Eltron

35 on a Stiebel Eltron heat pump: Min. flow, cooling: Refrigerant inlet pressure below threshold during cooling; heat pump locked out, restarts after idle period if temperature rises

Short answer

On a Stiebel Eltron heat pump, 35 means: Min. flow, cooling: Refrigerant inlet pressure below threshold during cooling; heat pump locked out, restarts after idle period if temperature rises. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

The manual says: Min. flow, cooling: Refrigerant inlet pressure below threshold during cooling; heat pump locked out, restarts after idle period if temperature rises.

Part involved: compressor / expansion valve / pressure switches.

When it shows: Refrigerant inlet pressure below threshold during cooling; heat pump locked out, restarts after idle period if temperature rises.

Likely causes:

  • BT42 condenser (frost protection) temperature below 6.5 °C for more than 10 seconds.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

The manual says: Min. flow, cooling: Refrigerant inlet pressure below threshold during cooling; compressor blocked.

Part involved: compressor / expansion valve / pressure switches.

When it shows: Refrigerant inlet pressure below threshold during cooling; compressor blocked.

Is it safe?

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

Does the heat pump stop?Yes
SeverityWarning
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: unknown.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the fault number shown on the programming unit display.
  • Check the appliance breakers/MCBs at the consumer unit are on.

What the engineer will check

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

  • Select a higher pump speed.

Who to ask for: F-gas/refrigeration-qualified heat pump engineer (R290/A3 flammable-refrigerant competence for R290 models).

Certification: F-gas certification for fluorinated refrigerants (R410A/R454C); flammable refrigerant (R290) handling training for R290 models.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

  • Follow remedy in LWZ 304/404 SOL installation manual section 9.4; causes largely parallel LWZ 5-8 list.

Who to ask for: F-gas/refrigeration-qualified heat pump engineer (R290/A3 flammable-refrigerant competence for R290 models).

Certification: F-gas certification for fluorinated refrigerants (R410A/R454C); flammable refrigerant (R290) handling training for R290 models.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026