02Stiebel Eltron

02 on a Stiebel Eltron heat pump: The high limit safety cut-out has tripped: The electric emergency/booster heater has overheated and was stopped by the high limit safety cut-out

Short answer

On a Stiebel Eltron heat pump, 02 means: The high limit safety cut-out has tripped: The electric emergency/booster heater has overheated and was stopped by the high limit safety cut-out. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

The manual says: The high limit safety cut-out has tripped: The electric emergency/booster heater has overheated and was stopped by the high limit safety cut-out.

Part involved: water flow / pump / booster heater.

When it shows: The electric emergency/booster heater has overheated and was stopped by the high limit safety cut-out.

Likely causes:

  • Flow rate through the heat pump too low; external filter on the return contaminated; pump seized; all radiator thermostatic valves/UFH zone valves closed (heating curve too high); POWER-OFF parameter set incorrectly for utility power-off periods.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

The manual says: The high limit safety cut-out has tripped: Electric emergency/booster heater overheated and was stopped by the high limit safety cut-out.

Part involved: water flow / pump / booster heater.

When it shows: Electric emergency/booster heater overheated and was stopped by the high limit safety cut-out.

Is it safe?

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: electronics reset button / STB reset per manual.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

  • Note the fault number shown on the programming unit display.
  • Check the appliance breakers/MCBs at the consumer unit are on.
  • Check that some radiator/underfloor zone valves are open and the heating curve/room set temperature is not unusually high.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

  • Note the fault number shown on the programming unit display.
  • Check the appliance breakers/MCBs at the consumer unit are on.

What the engineer will check

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

  • Clean the filter; ensure pump function or replace pump; match heating curve; check power-OFF contact/parameter; press the high limit safety cut-out reset button and the electronics reset button. If the fault recurs, inform your qualified contractor.

Who to ask for: Heating / heat pump engineer.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

  • Follow remedy in LWZ 304/404 SOL installation manual section 9.4; causes largely parallel LWZ 5-8 list.

Who to ask for: Heating / heat pump engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026