SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Stiebel Eltron
03Stiebel Eltron

03 on a Stiebel Eltron heat pump: High pressure switch: The high pressure switch has responded five times within a compressor runtime of two hours. The heat pump will shut down

Short answer

On a Stiebel Eltron heat pump, 03 means: High pressure switch: The high pressure switch has responded five times within a compressor runtime of two hours. The heat pump will shut down. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

The manual says: High pressure switch: The high pressure switch has responded five times within a compressor runtime of two hours. The heat pump will shut down.

Part involved: compressor / expansion valve / pressure switches.

When it shows: The high pressure switch has responded five times within a compressor runtime of two hours. The heat pump will shut down.

Likely causes:

  • External filter on the return contaminated; pump seized; flow rate too low (all valves closed / heating curve too high).

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

The manual says: High pressure switch: High pressure switch responded five times in five hours; heat pump shuts down.

Part involved: compressor / expansion valve / pressure switches.

When it shows: High pressure switch responded five times in five hours; heat pump shuts down.

Is it safe?

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: unknown.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

  • Note the fault number shown on the programming unit display.
  • Check the appliance breakers/MCBs at the consumer unit are on.
  • Check that some radiator/underfloor zone valves are open and the heating curve/room set temperature is not unusually high.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

  • Note the fault number shown on the programming unit display.
  • Check the appliance breakers/MCBs at the consumer unit are on.

What the engineer will check

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

  • Clean the filter; ensure pump function or replace; match heating curve; isolate the appliance across all poles from the mains for three minutes. If the fault recurs, inform your qualified contractor.

Who to ask for: F-gas/refrigeration-qualified heat pump engineer (R290/A3 flammable-refrigerant competence for R290 models).

Certification: F-gas certification for fluorinated refrigerants (R410A/R454C); flammable refrigerant (R290) handling training for R290 models.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

  • Follow remedy in LWZ 304/404 SOL installation manual section 9.4; causes largely parallel LWZ 5-8 list.

Who to ask for: F-gas/refrigeration-qualified heat pump engineer (R290/A3 flammable-refrigerant competence for R290 models).

Certification: F-gas certification for fluorinated refrigerants (R410A/R454C); flammable refrigerant (R290) handling training for R290 models.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026