04 on a Stiebel Eltron heat pump: Low pressure switch: The low pressure switch has responded five times in five hours. The heat pump will shut down

Short answer

On a Stiebel Eltron heat pump, 04 means: Low pressure switch: The low pressure switch has responded five times in five hours. The heat pump will shut down. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

The manual says: Low pressure switch: The low pressure switch has responded five times in five hours. The heat pump will shut down.

Part involved: ventilation module / fans / air sensors.

When it shows: The low pressure switch has responded five times in five hours. The heat pump will shut down.

Likely causes:

  • Exhaust air fan faulty (fault 07 also listed); fault in defrost detector; heat pump intake or discharge blocked.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

The manual says: Low pressure limiter: Low pressure switch responded five times in five hours; heat pump shuts down.

Part involved: compressor / expansion valve / pressure switches.

When it shows: Low pressure switch responded five times in five hours; heat pump shuts down.

Is it safe?

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: electronics reset button / STB reset per manual.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the fault number shown on the programming unit display.
  • Check the appliance breakers/MCBs at the consumer unit are on.

What the engineer will check

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

  • Check defrost hose for icing; check and clean intake/discharge; press the electronics reset button. If the fault recurs, inform your qualified contractor.

Who to ask for: MVHR/ventilation-competent heat pump engineer.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

  • Follow remedy in LWZ 304/404 SOL installation manual section 9.4; causes largely parallel LWZ 5-8 list.

Who to ask for: F-gas/refrigeration-qualified heat pump engineer (R290/A3 flammable-refrigerant competence for R290 models).

Certification: F-gas certification for fluorinated refrigerants (R410A/R454C); flammable refrigerant (R290) handling training for R290 models.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026