29 on a Stiebel Eltron heat pump: DHW temperature sensor: DHW heating is blocked
Short answer
On a Stiebel Eltron heat pump, 29 means: DHW temperature sensor: DHW heating is blocked. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.
Reviewed 23 September 2026 · 2 sources
What it means
On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)
The manual says: DHW temperature sensor: DHW heating is blocked.
Part involved: temperature/pressure sensor.
When it shows: DHW heating is blocked.
Likely causes:
- The measured sensor values have been constantly outside the permissible range for a specified period.
On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)
The manual says: DHW temperature sensor: DHW sensor values outside permissible range; DHW heating blocked.
Part involved: temperature/pressure sensor.
When it shows: DHW sensor values outside permissible range; DHW heating blocked.
Is it safe?
On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)
| Does the heat pump stop? | Partly |
|---|---|
| Severity | Fault — needs a manual reset once the cause is fixed |
| Engineer needed? | Yes |
The heat pump keeps running with some functions stopped.
Resetting itself: no.
Manual reset: electronics reset button / STB reset per manual.
On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)
| Does the heat pump stop? | Yes |
|---|---|
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
Resetting itself: unknown.
Manual reset: unknown.
What you can check
- Note the fault number shown on the programming unit display.
- Check the appliance breakers/MCBs at the consumer unit are on.
What the engineer will check
On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)
- Press the electronics reset button for one second. If the fault recurs, inform your qualified contractor.
Who to ask for: Heat pump service engineer (electrical/controls).
Certification: Qualified electrician competence for live-work on appliance electrics.
On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)
- Follow remedy in LWZ 304/404 SOL installation manual section 9.4; causes largely parallel LWZ 5-8 list.
Who to ask for: Heat pump service engineer (electrical/controls).
Certification: Qualified electrician competence for live-work on appliance electrics.
What you might notice
Sources
- COMMISSIONING AND NOTIFICATION LIST LWZ 8 CS Premium / LWZ 5 CS Premium / LWZ 5 S Plus / LWZ 8 CS Trend / LWZ 8 S Trend / LWZ 5 S Trend / LWZ 5 S Smart (doc-00081766) ↗ · A 338916-45679-9862 · page 18 · Reviewed 23 September 2026
- INSTALLATION LWZ 304 SOL / LWZ 404 SOL (English, via ManualsLib manual 1279865) ↗ · page 43 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026