22Stiebel Eltron

22 on a Stiebel Eltron heat pump: Hot gas temperature sensor: The compressor is switched off at outside temperatures < -10 °C and condenser temperatures > 40 °C

Short answer

On a Stiebel Eltron heat pump, 22 means: Hot gas temperature sensor: The compressor is switched off at outside temperatures < -10 °C and condenser temperatures > 40 °C. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

The manual says: Hot gas temperature sensor: The compressor is switched off at outside temperatures < -10 °C and condenser temperatures > 40 °C.

Part involved: temperature/pressure sensor.

When it shows: The compressor is switched off at outside temperatures < -10 °C and condenser temperatures > 40 °C.

Likely causes:

  • The measured sensor values have been constantly outside the permissible range for a specified period.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

The manual says: Hot gas temperature sensor: Hot gas sensor values outside permissible range.

Part involved: temperature/pressure sensor.

When it shows: Hot gas sensor values outside permissible range.

Is it safe?

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: electronics reset button / STB reset per manual.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the fault number shown on the programming unit display.
  • Check the appliance breakers/MCBs at the consumer unit are on.

What the engineer will check

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

  • Press the electronics reset button for one second. If the fault recurs, inform your qualified contractor.

Who to ask for: Heat pump service engineer (electrical/controls).

Certification: Qualified electrician competence for live-work on appliance electrics.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

  • Follow remedy in LWZ 304/404 SOL installation manual section 9.4; causes largely parallel LWZ 5-8 list.

Who to ask for: Heat pump service engineer (electrical/controls).

Certification: Qualified electrician competence for live-work on appliance electrics.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.