16 on a Stiebel Eltron heat pump: Inverter communication fault

Short answer

On a Stiebel Eltron heat pump, 16 means: Inverter communication fault. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

The manual says: Inverter communication fault.

Part involved: compressor or fan inverter.

When it shows: Inverter communication fault.

Likely causes:

  • Communication fault between control and inverter.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

The manual says: EVE no output: Expansion valve electronics: no output.

Part involved: compressor / expansion valve / pressure switches.

When it shows: Expansion valve electronics: no output.

Is it safe?

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

Does the heat pump stop?Partly
SeverityWarning
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no.

Manual reset: unknown.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the fault number shown on the programming unit display.
  • Check the appliance breakers/MCBs at the consumer unit are on.

What the engineer will check

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

  • Notify your qualified contractor.

Who to ask for: Heat pump service engineer (electrical/controls).

Certification: Qualified electrician competence for live-work on appliance electrics.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

  • Follow remedy in LWZ 304/404 SOL installation manual section 9.4; causes largely parallel LWZ 5-8 list.

Who to ask for: F-gas/refrigeration-qualified heat pump engineer (R290/A3 flammable-refrigerant competence for R290 models).

Certification: F-gas certification for fluorinated refrigerants (R410A/R454C); flammable refrigerant (R290) handling training for R290 models.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026