15 on a Stiebel Eltron heat pump: DHW temperature: DHW heating blocked until 22:00 h if set DHW temperature not reached within 'MAX DHW HTG DUR.'; retried, then blocked until 22:00 next day

Short answer

On a Stiebel Eltron heat pump, 15 means: DHW temperature: DHW heating blocked until 22:00 h if set DHW temperature not reached within 'MAX DHW HTG DUR.'; retried, then blocked until 22:00 next day. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

The manual says: DHW temperature: DHW heating blocked until 22:00 h if set DHW temperature not reached within 'MAX DHW HTG DUR.'; retried, then blocked until 22:00 next day.

Part involved: water flow / pump / booster heater.

When it shows: DHW heating blocked until 22:00 h if set DHW temperature not reached within 'MAX DHW HTG DUR.'; retried, then blocked until 22:00 next day.

Likely causes:

  • Booster heater stages not enabled or blocked by high limit safety cut-out; DHW diverter valve not working; 'MAX FLOW TEMP DHW' set too low.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

The manual says: DHW temperature: Set DHW temperature not reached in the defined time.

Part involved: unspecified.

When it shows: Set DHW temperature not reached in the defined time.

Is it safe?

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

Does the heat pump stop?Yes
SeverityWarning
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: electronics reset button / STB reset per manual.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

  • Note the fault number shown on the programming unit display.
  • Check the appliance breakers/MCBs at the consumer unit are on.
  • Check the DHW set temperature and schedule on the programming unit.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

  • Note the fault number shown on the programming unit display.
  • Check the appliance breakers/MCBs at the consumer unit are on.

What the engineer will check

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

  • Check/reset high limit safety cut-out (see 02); try 'DHW ECO'; test diverter valve by setting DHW to 10 °C and 50 °C; if the fault recurs, inform your qualified contractor.

Who to ask for: Heating / heat pump engineer.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

  • Follow remedy in LWZ 304/404 SOL installation manual section 9.4; causes largely parallel LWZ 5-8 list.

Who to ask for: Heating / heat pump engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026