Heat pumps · Error codes · Stiebel Eltron
12Stiebel Eltron

12 on a Stiebel Eltron heat pump: High pressure sensor: The high pressure sensor does not deliver a plausible signal (< 2 mA for longer than 10 s)

Short answer

On a Stiebel Eltron heat pump, 12 means: High pressure sensor: The high pressure sensor does not deliver a plausible signal (< 2 mA for longer than 10 s). The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

The manual says: High pressure sensor: The high pressure sensor does not deliver a plausible signal (< 2 mA for longer than 10 s).

Part involved: temperature/pressure sensor.

When it shows: The high pressure sensor does not deliver a plausible signal (< 2 mA for longer than 10 s).

Likely causes:

  • High pressure sensor fault or sensor lead.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

The manual says: HP sensor: High pressure sensor does not deliver a plausible signal (< 2 mA for longer than 10 s).

Part involved: temperature/pressure sensor.

When it shows: High pressure sensor does not deliver a plausible signal (< 2 mA for longer than 10 s).

Is it safe?

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

Does the heat pump stop?Partly
SeverityWarning
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no.

Manual reset: unknown.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the fault number shown on the programming unit display.
  • Check the appliance breakers/MCBs at the consumer unit are on.

What the engineer will check

On the LWZ 5/8 CS Premium, LWZ 5 S Plus, LWZ 5/8 S Trend, LWZ 5 S Smart (integral ventilation units)

  • Check the sensor lead. If the fault recurs, inform your qualified contractor.

Who to ask for: Heat pump service engineer (electrical/controls).

Certification: Qualified electrician competence for live-work on appliance electrics.

On the LWZ 304 SOL / LWZ 404 SOL (integral ventilation units)

  • Follow remedy in LWZ 304/404 SOL installation manual section 9.4; causes largely parallel LWZ 5-8 list.

Who to ask for: Heat pump service engineer (electrical/controls).

Certification: Qualified electrician competence for live-work on appliance electrics.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026