E913Samsung · Samsung, all models

E913 on a Samsung heat pump: Six times detection for Flow Switch Error (Re-operation is not possible)

Short answer

On a Samsung heat pump, E913 means: Six times detection for Flow Switch Error (Re-operation is not possible). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Six times detection for Flow Switch Error (Re-operation is not possible).

Part involved: Water pump and flow sensor/switch.

When it shows: Unit self-diagnosis: Six times detection for Flow Switch Error (Re-operation is not possible).

Likely causes:

  • Water flow too low or flow sensor/switch signal inconsistent with pump state: low system pressure, air in system, blocked strainer/filter, closed valve, pump fault, flow switch/sensor or PCB fault, or an external pump creating flow.
  • Engineer checks per Samsung service manual: Repeated flow switch errors (6 times): investigate water pump, flow switch, filter/strainer and water flow before re-operation.

Is it safe?

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: yes - re-operation not possible until investigated (per Samsung).

What you can check

  • Note the full error code shown on the controller; check the heat pump breaker/isolator in the consumer unit is ON; check the heating system pressure gauge reading (typically 1-2 bar when cold; do not top up unless you have been shown how); check the filling loop is closed; then contact your installer or Samsung service; Samsung manuals do not describe a homeowner reset for this code.

What the engineer will check

  • Repeated flow switch errors (6 times): investigate water pump, flow switch, filter/strainer and water flow before re-operation. Any work inside casings, on PCBs, wiring, sensors, pumps, valves or refrigerant is engineer-only.

Who to ask for: Heat pump installer (wet system / hydraulics).

Certification: None specific (plumbing competence); competent electrical worker for pump/PCB electrical tests.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026