E484 on a Samsung heat pump: PFC Overload Error

Short answer

On a Samsung heat pump, E484 means: PFC Overload Error. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: PFC Overload Error.

Part involved: Inverter PCB / compressor.

When it shows: Unit self-diagnosis: PFC Overload Error.

Likely causes:

  • Inverter/compressor drive fault: supply voltage issue, compressor wiring/winding, IPM/PFC/sensor fault on inverter PCB, refrigerant or airflow problem causing overcurrent/overheat.
  • Engineer checks per Samsung service manual: Check reactor in control box; if normal, exchange inverter PBA.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the full error code shown on the controller; check the heat pump breaker/isolator in the consumer unit is ON; check the outdoor unit is not blocked by leaves, debris or snow and air can flow freely; then contact your installer or Samsung service; Samsung manuals do not describe a homeowner reset for this code.

What the engineer will check

  • Check reactor in control box; if normal, exchange inverter PBA. Any work inside casings, on PCBs, wiring, sensors, pumps, valves or refrigerant is engineer-only.

Who to ask for: Heat pump engineer with electrical and refrigeration competence; R290 (A3 flammable refrigerant) competence.

Certification: Competent electrical worker (BS 7671); F-gas certification if refrigerant circuit is opened; R290/flammable refrigerant handling training (e.g. hydrocarbon refrigerant course).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026