U8 on a Mitsubishi Electric heat pump: Outdoor fan motor: rotational frequency abnormal / not detected during DC fan motor operation
Short answer
On a Mitsubishi Electric heat pump, U8 means: Outdoor fan motor: rotational frequency abnormal / not detected during DC fan motor operation. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 8 sources
What it means
The manual says: Outdoor fan motor: rotational frequency abnormal / not detected during DC fan motor operation.
Part involved: Outdoor DC fan motor.
When it shows: <= 100 rpm for 15 s at >= 20C outside air, or <= 50 rpm or >= 1500 rpm for 1 minute.
Likely causes:
- 1 Failure in operation of DC fan motor; 2 Failure of outdoor controller circuit board.
Is it safe?
| Does the heat pump stop? | Yes |
|---|---|
| Severity | Fault — needs a manual reset once the cause is fixed |
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
Resetting itself: Not stated as auto-recovering in the service manual; code is logged in the outdoor unit error history.
Manual reset: Clear via RESET on the main remote controller after the cause is fixed; service manual actions include switching power off and on to recheck.
What you can check
- Note the code, unit and ref. address shown on the main remote controller and contact your installer (Mitsubishi user manuals: 'Make a note of the error code number and contact installer'). Check the heat pump breaker/isolator at the consumer unit is on and read the primary system pressure gauge (if fitted) so you can report it. A single reset from the main remote controller (RESET, then Yes) may be tried; if the code returns, do not keep resetting. Do not open the outdoor unit, cylinder/hydrobox or any casing. Also check from a distance that the outdoor unit air inlet/outlet is not blocked by snow, ice, leaves or other debris (never reach into the fan).
What the engineer will check
- 1 Check or replace DC fan motor; 2 Check outdoor controller board voltage during operation; replace board if failure persists after replacing motor.
Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (controls / wiring).
What you might notice
What owners and engineers report
1 owner and engineer report mentions this.
- Outdoor unit frozen / iced up on the Ecodan Zubadan Puhz Shw Split: 1 report
Sources
- Ecodan PUHZ-SW(75-100-120)(V-Y)HA-BS Service Manual (OCH755) ↗ · OCH755 · page OCH755 p.25; OCH525C p.23 · Reviewed 23 September 2026
- Ecodan PUHZ-W112VHA-BS Service Manual (OCH562D) ↗ · OCH562D · page OCH562D p.20; OCH605A p.17; OCH465D p.22; OCH439N p.56 · Reviewed 23 September 2026
- PUZ-WZ(85-100-120)(V-Y)AA(-BS) Service_Manual (OCH880) ↗ · OCH880 · page OCH880 p.40; OCH816 p.36 · Reviewed 23 September 2026
- Ecodan PUZ-WM(50-60-85-112)V(H-A)A Service Manual (OCH727A) ↗ · OCH727A · page 26 · Reviewed 23 September 2026
- Ecodan PUZ-HWM140(V-Y)HA Service Manual (OCH748A) ↗ · OCH748A · page 23 · Reviewed 23 September 2026
- PUHZ-W85-112VAA(-BS) Service Manual (OCH681) ↗ · OCH681 · page 17 · Reviewed 23 September 2026
- Ecodan PUHZ-HW140VHA2-BS / PUHZ-HW140YHA2-BS Service Manual (OCH439N) ↗ · OCH439N · page 56 · Reviewed 23 September 2026
- PUHZ-SHW112-140V/YHA Service Manual (OCH526) ↗ · OCH526 · page 27 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026