SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Mitsubishi Electric
E8Mitsubishi Electric

E8 on a Mitsubishi Electric heat pump: Indoor/outdoor unit communication error - signal receiving error detected by outdoor unit (nothing received normally for 3 minutes)

Short answer

On a Mitsubishi Electric heat pump, E8 means: Indoor/outdoor unit communication error - signal receiving error detected by outdoor unit (nothing received normally for 3 minutes). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 8 sources

What it means

The manual says: Indoor/outdoor unit communication error - signal receiving error detected by outdoor unit (nothing received normally for 3 minutes).

Part involved: Indoor/outdoor connecting wire; outdoor/indoor controller boards.

When it shows: Outdoor controller board cannot receive anything normally for 3 minutes.

Likely causes:

  • 1 Contact failure of indoor/outdoor unit connecting wire; 2 Defective communication circuit of outdoor controller circuit board; 3 Defective communication circuit of indoor controller board; 4 Noise has entered indoor/outdoor connecting wire.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated as auto-recovering in the service manual; code is logged in the outdoor unit error history.

Manual reset: Clear via RESET on the main remote controller after the cause is fixed; service manual actions include switching power off and on to recheck.

What you can check

  • Note the code, unit and ref. address shown on the main remote controller and contact your installer (Mitsubishi user manuals: 'Make a note of the error code number and contact installer'). Check the heat pump breaker/isolator at the consumer unit is on and read the primary system pressure gauge (if fitted) so you can report it. A single reset from the main remote controller (RESET, then Yes) may be tried; if the code returns, do not keep resetting. Do not open the outdoor unit, cylinder/hydrobox or any casing. A power cycle is a Mitsubishi first step for communication codes: switching the heat pump off and on at its isolator (outdoor and indoor supplies) once is acceptable.

What the engineer will check

  • 1 Check disconnection or looseness of indoor/outdoor connecting wire; 2-4 Turn power off and on again; replace indoor or outdoor controller board if displayed again.

Who to ask for: Mitsubishi Ecodan-trained heat pump engineer (controls / wiring).

What you might notice

What owners and engineers report

1 owner and engineer report mentions this.

  • Intermittent fault on the Ecodan Ultra Quiet Puhz W Vaa: 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026