HP on an IVT Greenline HT Plus: Pressure switch high (HP) tripped

Short answer

On an IVT heat pump, HP means: Pressure switch high (HP) tripped. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Pressure switch high (HP) tripped.

Part involved: high pressure switch.

Likely causes:

  • Air in the heating system; not enough flow over the heat pump (pump stopped, closed valves - thermostatic valves should be fully open, at least half of floor coils open); particle filter on hot side clogged; refrigerant circuit overfilled; drying filter clogged.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Manual reset: Ackn. button on Rego 637 control panel.

What you can check

  • Press the Ackn. button on the control panel once (the manual says there is no risk in resetting an alarm; the heat pump restarts within 15 minutes if heat is needed). If the alarm returns, contact your installer. Check the heating-system pressure gauge is in the range given in the user guide (Thermia/Danfoss: 1-1.5 bar when cold) - do not top up yourself unless you have been shown how; check radiator/underfloor valves and room thermostats are open.

What the engineer will check

  • Vent radiators and refill heating system; check heat carrier pump running and speed; clean hot-side particle filter; check charge; check drier.

Who to ask for: heat pump engineer.

Certification: F-Gas category I certificate (refrigerant circuit work).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.