Heat pumps · Error codes · IVT
GT9IVT · Greenline HT Plus

GT9 on an IVT Greenline HT Plus: High return to the heat pump T9 (GT9): compressor stopped because return water temperature is too high (limit approx. 58°C)

Short answer

On an IVT heat pump, GT9 means: High return to the heat pump T9 (GT9): compressor stopped because return water temperature is too high (limit approx. 58°C). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: High return to the heat pump T9 (GT9): compressor stopped because return water temperature is too high (limit approx. 58°C).

Part involved: return sensor GT9.

Likely causes:

  • Heating setting too high; radiator/floor valves closed; hot water temperature set too high (alarm in hot water mode); flow across heat pump greater than heating system flow (bypass fitted).

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Yes.

What you can check

  • Lower the heating setting (Temp. incr./decr.) on the controller; make sure radiator/underfloor valves are open; then press Ackn. If it occurs in hot water mode, ask the installer to adjust the hot water temperature.

What the engineer will check

  • Adjust heat carrier/main pump speeds where a bypass is fitted; check hot water setting.

Who to ask for: heat pump engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026