Immergas heat pump error codes

Immergas · A niche brand in the UK. 65 codes across 1 product family, each taken from the manufacturer’s manuals. Immergas technical support ↗

Find a Immergas engineer →65 codes · reviewed 23 September 2026

Search within brand

Type the code on your display or a word from its meaning. Each code opens its own page with what it means, whether it is safe and what you can check.

65 codes

CodeMeaningStops?Homeowner check?
C7
Temperature of transducer (inverter) module too high
Not statedYes
E0
Water flow fault (after E8 has been displayed 3 times)
Not statedYes
E1
Phase loss, or neutral/live connected inversely (three-phase units only)
Not statedYes
E2
Communication fault between the control panel and the hydraulic module
Not statedYes
E3
Fault of final outlet water temperature sensor (T1)
Not statedYes
E4
Fault of DHW storage tank temperature sensor (T5)
Not statedYes
E5
Error of refrigerant temperature sensor exiting the condenser (T3)
Not statedYes
E6
Error of room (outdoor ambient) temperature sensor (T4)
Not statedYes
E7
Fault of buffer tank temperature sensor (Tbt1)
Not statedYes
E8
Water flow fault
Not statedYes
E9
Error of compressor intake (suction) temperature sensor (Th)
Not statedYes
EA
Error of compressor discharge ('drain') temperature sensor (Tp)
Not statedYes
Eb
Error of solar panel temperature sensor (Tsolar)
Not statedYes
EC
Error of low temperature sensor (Tbt2) of the thermostat manifold/buffer
Not statedYes
Ed
Error of plate heat exchanger inlet water temperature sensor (Tw_in)
Not statedYes
EE
EEPROM fault of the hydraulic module main control board
Not statedYes
EP
Leakage fault on tank booster heater (TBH)
Not statedYes
F1
Low voltage protection on DC bus
Not statedYes
H0
Communication fault between hydraulic module main board and main control board PCB B
Not statedYes
H1
Communication error between inverter module PCB A and main control board PCB B
Not statedYes
H2
Fault of refrigerant outlet temperature sensor (T2) of plate heat exchanger (liquid pipe)
Not statedYes
H3
Fault of refrigerant outlet temperature sensor (T2B) of plate heat exchanger (gas pipe)
Not statedYes
H4
Protection for three times P6 (L0/L1) in an hour
Not statedYes
H5
Fault of room temperature sensor (Ta) in the control panel
Not statedYes
H6
Fault of fan motor
Not statedYes
H7
Main circuit voltage protection fault
Not statedYes
H8
Fault of pressure sensor
Not statedYes
H9
Fault of zone 2 water temperature sensor (Tw2)
Not statedYes
HA
Fault of outlet water temperature sensor (Tw_out)
Not statedYes
Hb
Protection 'PP' three times and Tw_out < 7C
Not statedYes
Hd
Communication fault between hydraulic modules in parallel (cascade)
Not statedYes
HE
Communication error between main board and thermostat transfer board
Not statedYes
HF
EEPROM fault of the inverter module board
Not statedYes
HH
H6 appeared 10 times in 2 hours
Not statedYes
HP
Low pressure protection in cooling (Pe < 0.6) occurred 3 times in one hour
Not statedYes
L0
Compressor inverter module fault
Not statedYes
L1
Low voltage protection on DC bus
Not statedYes
L2
High voltage protection on DC bus
Not statedYes
L4
MCE operation anomaly
Not statedYes
L5
Zero speed protection
Not statedYes
L7
Phase sequence fault (three-phase models only)
Not statedYes
L8
Compressor frequency variation higher than 15 Hz within 1 second
Not statedYes
L9
Actual compressor frequency differs from target by over 15 Hz
Not statedYes
P0
Low pressure protection switch
Not statedYes
P1
High pressure protection switch
Not statedYes
P3
Protection against compressor overcurrent
Not statedYes
P4
Compressor discharge ('flow') temperature too high protection
Not statedYes
P5
High temperature difference between water inlet and outlet of plate heat exchanger (Tw_out - Tw_in)
Not statedYes
P6
Inverter module protection
Not statedYes
P9
Fan protection
Not statedYes
Pb
Antifreeze protection
PartlyYes
Pd
High temperature protection of refrigerant outlet temperature in the condenser
Not statedYes
PP
Inlet water temperature higher than outlet in heating mode (Tw_in > Tw_out)
Not statedYes
PUMP-E04
Circulation pump LED code: Grid undervoltage
YesYes
PUMP-E05
Circulation pump LED code: Grid overvoltage
YesYes
PUMP-E07
Circulation pump LED code: Generator operation (warning)
PartlyYes
PUMP-E09
Circulation pump LED code: Turbine operation
YesYes
PUMP-E10
Circulation pump LED code: Block
YesYes
PUMP-E11
Circulation pump LED code: Dry operation (warning)
PartlyYes
PUMP-E21
Circulation pump LED code: Overload
YesYes
PUMP-E23
Circulation pump LED code: Short-circuit
YesYes
PUMP-E25
Circulation pump LED code: Contact/winding
YesYes
PUMP-E30
Circulation pump LED code: Module overheated
YesYes
PUMP-E31
Circulation pump LED code: Power section overheated
YesYes
PUMP-E36
Circulation pump LED code: Electronic failures
YesYes