P0Immergas · MAGIS M monobloc R32 (M4-M30 T) - sold in UK as Alpha Magis M

P0 on an Immergas MAGIS M monobloc R32 - sold in UK as Alpha Magis M: Low pressure protection switch

Short answer

On an Immergas heat pump, P0 means: Low pressure protection switch. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Low pressure protection switch.

Likely causes:

  • Lack of refrigerant.
  • Outdoor coil dirty/blocked (heating/DHW).
  • Low water flow in cooling.
  • EXV blocked or winding connector loose.

Is it safe?

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Manual reset: Manual 13.4: reset the safety device by switching the unit off and back on; if this fails contact your local dealer.

What you can check

  • Check the outdoor unit is not blocked by leaves, debris or snow and has clear airflow.
  • Note the code on the control panel and contact the installer / Alpha-Immergas authorised service.
  • The manual says to reset the safety device by switching the unit off and back on; if the reset fails, contact the dealer - do not keep resetting.

What the engineer will check

  • Lack of refrigerant.
  • Outdoor coil dirty/blocked (heating/DHW).
  • Low water flow in cooling.
  • EXV blocked or winding connector loose.
  • Refrigerant-circuit diagnosis/charging (F-gas certified engineer).

Who to ask for: heat pump / refrigeration engineer.

Certification: F-gas certification for refrigerant circuit work (unit is hermetically sealed; installation needs no F-gas per Alpha).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026