Er35 on a Cool Energy Pro Range CE-H: Compressor over current protection

Short answer

On a Cool Energy heat pump, Er35 means: Compressor over current protection. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Compressor over current protection.

Likely causes:

  • Compressor over current.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the heat pump's breaker/isolator at the consumer unit is switched on (do not repeatedly reset if it trips).

What the engineer will check

  • Check incoming voltage.
  • Check if compressor is overloaded.
  • Check thermal relay and replace if damaged.
  • Check compressor windings and wiring/phase sequence.
  • Check inverter drive parameters match compressor model.
  • Check operating envelope (flow, pressures, load).

Who to ask for: refrigeration / F-gas heat pump engineer.

Certification: F-gas certification; electrical competence.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.