Er05Cool Energy

Er05 on a Cool Energy heat pump: High refrigerant pressure

Short answer

On a Cool Energy heat pump, Er05 means: High refrigerant pressure. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the ecoTech DC Inverter (R32 EVI)

The manual says: High refrigerant pressure.

On the Inverter range CE-iH (R410A, c.2020)

The manual says: Evaporator temperature probe fault.

On the Pro Range CE-H (fixed-speed)

The manual says: Compressor high pressure discharge.

When it shows: High pressure detected on compressor (p.24).

Likely causes:

  • Water tank sensor incompatible or mispositioned.
  • Y-shaped filter blocked.
  • Plumbing blocked.
  • Too much air in plumbing reducing flow.
  • Circulation pump faulty or too small.
  • Excessive refrigerant charge.
  • HP switch control cable damaged/disconnected.
  • HP switch cannot be reset.
  • HP sensor input shorted.
  • Refrigeration system blocked by ice or dirt.

Is it safe?

On the ecoTech DC Inverter (R32 EVI)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

On the Inverter range CE-iH (R410A, c.2020)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

On the Pro Range CE-H (fixed-speed)

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Resumes 3 min after HP switch reset.

Manual reset: Permanently disabled after 3 occurrences in 1 hour.

What you can check

On the ecoTech DC Inverter (R32 EVI)

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the heating system pressure gauge reading against the value in your handover documents (manufacturer commissioning values: typically 1-2 bar) and that the filling loop is closed.
  • Check the outdoor unit/air grilles are not blocked by debris, leaves or snow.

On the Inverter range CE-iH (R410A, c.2020)

  • Read and note the code shown on the controller display, then contact your installer or service engineer.

On the Pro Range CE-H (fixed-speed)

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the heating system pressure gauge reading against the value in your handover documents (manufacturer commissioning values: typically 1-2 bar) and that the filling loop is closed.
  • Check the outdoor unit/air grilles are not blocked by debris, leaves or snow.

What the engineer will check

On the ecoTech DC Inverter (R32 EVI)

  • Check water flow first (high pressure is often caused by low flow).
  • Check refrigerant pressures/temperatures with gauges (F-gas qualified).
  • Check for refrigerant leak or blockage, EEV operation and pressure switches/transducers.

Who to ask for: refrigeration / F-gas heat pump engineer.

Certification: F-gas certification (Category I) for refrigerant circuit work.

On the Inverter range CE-iH (R410A, c.2020)

  • Check the named sensor/probe connection at the PCB (loose/oxidised plug).
  • Measure sensor resistance against the manufacturer table and replace if faulty.
  • Check controller/PCB if sensor is good.

Who to ask for: heat pump controls / electrical.

Certification: Electrical competence.

On the Pro Range CE-H (fixed-speed)

  • Clean the Y filter.
  • Remove air and check circulation pump.
  • Charge correct refrigerant volume.
  • Replace HP switch/cable or PC board.
  • Clear refrigerant blockage and re-vacuum.
  • Check water flow first (high pressure is often caused by low flow).
  • Check refrigerant pressures/temperatures with gauges (F-gas qualified).
  • Check for refrigerant leak or blockage, EEV operation and pressure switches/transducers.

Who to ask for: refrigeration / F-gas heat pump engineer.

Certification: F-gas certification (Category I) for refrigerant circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.